If generator and grid are both available, the grid is used first. Generator capacity should be at least 1.3× the inverter rating. Shut down the inverter before changing GEN settings.
GEN
GEN Port
GENFunction of the GEN port
Generator
Start / Stop
Dry Force
Auto
Run Cycle
None
Start TimeHH:MM
00:00
End TimeHH:MM
00:00
Start by Battery Voltage
48.0V
Stop by Battery Voltage
60.0V
Power & Runtime
Max. Input Power
6600W
Peak Shaving
Max. Charge Power
6600W
Down Time
0min
Max. Runtime0 = unlimited
0min
GEN
GEN Port
GENFunction of the GEN port
Smart load
Min. PV Power with Smart Load On
500W
Start by Battery Voltage
60.0V
Stop by Battery Voltage
40.0V
Always On with GridSmart load stays on while the grid is present
GEN
GEN Port
GENFunction of the GEN port
AC coupling
Start by Battery Voltage
40.0V
Stop by Battery Voltage
60.0V
AC Couple High FrequencyDerates the grid-tied inverter
52.00Hz
The grid-tied inverter's rated power must be lower than the hybrid inverter's.